General Equipment

Product Overview

 

Thermostatic Water Baths and High-Temperature Sand Baths are precision laboratory heating devices designed for temperature-controlled sample preparation, incubation, and thermal treatment procedures. Water baths utilize a liquid medium for uniform, gentle heating, while sand baths provide dry thermal transfer for high-temperature laboratory vessels and solid samples.


The two product series serve distinct temperature requirements and operational workflows.


Thermostatic Water Bath Series
Engineered for laboratory procedures requiring controlled liquid immersion heating across an operating range from ambient +5°C to 100°C. Primary applications include reagent pre-heating, biological incubation, enzyme assays, and general laboratory warming, subject to specific protocol requirements and thermal load limits.


High-Temperature Sand Bath Series
Designed for elevated dry heating procedures exceeding the operational limit of liquid water baths, offering a maximum working temperature of 400°C. Typical applications include heating heat-resistant crucibles, digestion flasks, and inorganic compounds, depending on sample stability and vessel material properties.
Final model selection should be determined based on target working temperature, sample chemistry, vessel geometry, required bath capacity, thermal stability requirements, and regional power specifications.

 
 

Technical Specifications

 

Specification Parameter

TB-10L

TB-20L

TS-300

Bath Architecture

Single-Row Water Bath

Double-Row Water Bath

High-Temperature Sand Bath

Stated Nominal Capacity

10 L

20 L

12 L sand bed volume

Operating Temperature Range

Ambient +5°C to 100°C

Ambient +5°C to 100°C

Ambient +50°C to 400°C

Stated Temperature Stability

±0.1°C

±0.1°C

±1.0°C

Stated Temperature Uniformity

±0.2°C at 37°C

±0.2°C at 37°C

±2.0°C at 200°C

Heating Power Rating

800 W

1,500 W

2,000 W

Internal Chamber Dimensions (W × D × H)

300 × 240 × 150 mm

500 × 300 × 150 mm

320 × 320 × 100 mm

 

Hamburg Wheel Tracking Machine

Structural Design and Engineering Features

Chamber construction, insulation efficiency, housing finishes, and cover configurations directly impact operational durability, thermal retention, and operator safety.


Inner Chamber
Material Integrity: Constructed with a deep-drawn SUS304 stainless steel inner liner, featuring smooth radiused corners to reduce fluid entrapment and facilitate routine decontamination.
Chemical Compatibility Advisory: While SUS304 stainless steel offers excellent resistance to aqueous solutions and organic reagents, suitability for aggressive inorganic acids, high-concentration saline solutions, or halogenated compounds must be evaluated based on operating temperature, chemical exposure duration, and cleaning protocols.


Thermal Insulation and Outer Enclosure
Thermal Insulation: Engineered with high-density, multi-layer insulation matrices to minimize exterior thermal radiation, lower energy consumption, and preserve chamber thermal equilibrium.
Outer Housing: Formed from heavy-gauge cold-rolled steel treated with an electrostatic powder coating to protect against physical impact, moisture, and common chemical splash hazards.


Lids and Covers
Gabled Stainless Steel Lids: Recommended for high-temperature water bath operations to reduce fluid loss through evaporation, prevent condensation droplets from falling directly onto samples, and optimize power efficiency.
Concentric Ring Sets: Available for flexible vessel immersion, allowing simultaneous accommodation of varying flask diameters.

 

Control Architecture and Operational Safety

Temperature Control Mechanism

Microprocessor PID Logic: Integrates proportional-integral-derivative control algorithms paired with Solid-State Relay (SSR) switching to ensure precise power modulation and thermal overshoot protection.
Performance Note: Temperature stability, spatial uniformity, and heat-up rates represent distinct thermal properties that depend significantly on fluid convection, sample loading density, and lid usage.

Safety Engineering

Secondary Thermal Limits: Equipped with independent secondary thermal cut-off devices designed to isolate heater power in the event of an over-temperature condition.
Operational Safety Guidelines: Users must ensure minimum fluid fill levels in water baths prior to energizing heating elements. Automated low-fluid level sensors or secondary cutoff options should be explicitly confirmed during model configuration if extended or unattended operation is intended.

Quality and Safety Compliance

Manufactured in general alignment with recognized international safety guidelines for laboratory electrical equipment (including principles outlined in IEC/EN 61010 standards). Formal certification documentation and test declarations can be provided based on destination market regulatory requirements.

 

Applications and Operational Reference

 

 

Thermostatic Water Bath Applications
Sample Preparation and Thawing: Reagent warming, media pre-heating, and thermal preparation under controlled liquid immersion.
Biological Assays and Incubation: Temperature-sensitive biological reactions requiring strict thermal equilibrium near 37°C or specified incubation setpoints.
Industrial Quality Control: Material conditioning, petroleum testing protocols, and food and beverage quality analysis.

 

High-Temperature Sand Bath Applications
Crucible and High-Temperature Vessel Heating: Dry thermal transfer for ceramic crucibles, silica glass, or metallic vessels requiring temperatures up to 400°C.
Chemical Digestion and Evaporation Support: Controlled dry thermal assistance for sample digestion or reagent concentration where open flames or direct hotplates are unsuitable.
Materials Testing: Thermal exposure testing for polymers, asphalt, grease, and industrial resins.

 

Baseline Heat-Up Reference Times

Parameter

Reference Value

Test Context Notes

Water Bath Heat-Up Time

Ambient to 37°C in ≤25 min

Standard fluid volume, gabled lid closed

Sand Bath Heat-Up Time

Ambient to 300°C in ≤45 min

Standard sand bed thickness, unloaded

 

Manufacturing Quality Control and Documentation

 

To meet the stringent documentation requirements of international procurement groups, distributors, and accredited laboratories, rigorous testing protocols are implemented throughout the manufacturing process. 

 

Inspection Protocols
Chamber Integrity Inspection: Inner chambers undergo fluid containment testing prior to final insulation and cabinet assembly.
Electrical Safety and Functional Run: 100% testing of ground continuity, insulation resistance, controller switching logic, SSR responsiveness, and safety cut-offs.
Thermal Calibration and Verification: Temperature accuracy is verified using calibrated multi-point thermal probes against certified factory reference standards. 

 

Available Quality Documentation (Per Project Request)

Document

Description

Availability Status

Factory Inspection Certificate

Standard

Supplied upon request

Temperature Calibration / Test Protocol

Temperature verification documentation

Available upon request

Electrical Wiring Schematic

Electrical wiring information

Included in standard operational manual

English User Manual

Operating instructions

Included with each equipment unit

SUS304 Material Test Certificate (MTC)

Material documentation

Available for project and OEM orders

 

FAQ

 

Q: How do I select between a thermostatic water bath and a high-temperature sand bath?

A: Select a Water Bath when your laboratory procedure requires gentle, uniform heating in a liquid medium up to 100°C. Select a Sand Bath when your protocol requires dry thermal transfer at higher temperatures (up to 400°C) for crucibles or specialized vessels that cannot be exposed to liquid immersion.

Q: Will my custom tube racks or microplates fit into the working chamber?

A: Please review the internal chamber dimensions listed in Section 2 (W × D × H) against the outer footprint of your rack or container assembly. Custom rack inserts and modified lid options can be evaluated during quotation upon request.

Q: Can these units be operated continuously overnight?

A: Continuous or unattended operation depends on facility safety protocols, target operating temperature, and medium evaporation rates. For water baths, fluid levels must be continuously maintained or monitored to prevent dry heating. Always verify secondary over-temperature limit settings prior to executing long-duration thermal cycles.

Q: What compliance and inspection documents are supplied with shipment?

A: Every unit is shipped with an English operational manual. Factory inspection reports, multi-point calibration protocols, and material test certificates can be included upon request. Please list your required compliance documentation in your RFQ.

Q: What is the standard production lead time, and how are power supply options confirmed?

A: Production lead time depends on order volume, factory scheduling, and specific voltage configurations. Units are built tailored to destination electrical standards (110V or 220V with local plug types). Firm delivery estimates and commercial terms will be detailed in your formal quotation.

Zhuozhou Tianpeng Imp. and Exp. Trade Co., Ltd. is one of the most professional general equipment manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to buy advanced general equipment made in China here from our factory. Customized orders are welcome.